010
Symptom: Parking heater fails to start.
| 010 | 
 
  
  Fault symptom
Parking heater fails to start.Condition
Parking heater activated.B+ greater than 16 V.
Diagnostic help
Parking heater can be activated with Tech 2.Parking heater function can be programmed in SID.
Eberspächer diagnostics instrument used for diagnosis.
Diagnostic procedure
 
   
   1 Check the battery
| • | Check that no battery charger is connected to the battery. | |
| • | Start the engine. | |
| • | Check battery voltage at different engine rpm. | |
| • | Red test lead: B+. | |
| • | Black test lead: B-. | |
| • | The reading obtained should be below 15.5 V. | |
Test results OK?
| YES | 
   
   
    
     
      
   
   
        
     
    
        -
        
       
        Go to point 3.
         
      
        
       
  
| NO | 
   
   
    
     
      
   
   
        
     
    
        -
        
       
        Go to point 2.
         
      
        
       
  
2 Check the component
 
  
  | • | Check the accumulator and the regulator. See group 3 Electrical system, ’Components’. | |
Test results OK?
| YES | 
   
   
    
     
      
   
   
        
     
    
        -
        
       
        Go to point 3.
         
      
        
       
  
| NO | 
   
   
    
     
      
   
   
    
        
     
    
        -
        
       
        Repair or replace the faulty component.
         
      
        
       
     
      
   
   
        
     
    
        -
        
       
        Go to point 3.
         
      
        
       
  
3. Final check
 
  
  | • | Delete DTCs in all systems. | |
| • | Contact: SID. | |
| • | Activate parking heater (ON). | |
| • | Perform a functionality check. | |
| • | Evaluate the functionality check. | |
| • | Check that the diagnostic trouble code has not recurred. | |
Test results OK?
| YES | 
   
   
    
     
      
   
   
        
     
    
        -
        
       
        Fault rectified successfully.
         
      
        
       
  
| NO | 
   
   
    
     
      
   
   
        
     
    
        -
        
       
        See ’Procedure for replacement of control module’.
         
      
        
       
  

 
     
		