Main relay
Main relay |
When the ignition is in position "ON", +15 will be supplied to control module pin 43. The control module will then ground pin 26 to activate the main relay. From main relay pin 87, the control module will simultaneously receive supply voltage on pin 1. The control module supply is used internally to supply the throttle motor.
When the ignition switch is turned to “OFF”, the main relay remains operated for a further 10 seconds to allow adaptation of the throttle valve's fully closed position.
Diagnosis |
• |
Diagnostic trouble code P1652 will be generated in the event of a break or short-circuit to ground.
|
• |
Diagnostic trouble code P1653 will be generated in the event of a short-circuit to B+.
|
• |
If the supply of current to control module pin 1 fails, trouble code P1640 will be generated. As a result, the throttle closes and the engine stops.
|