SAAB WIS ONLINE

B2017

Read the instructions below then start the fault diagnostic procedure.

Symptom: No fan function in the seat.

B2017


Seat Ventilation Circuit Right - Short to B+

Seat Ventilation Circuit Right - Short to Ground


Fault symptoms


No fan function in the seat.


Type of diagnostics


- Continuous


Input conditions:


- Ignition ON


Fault criteria


- The voltage is below 0.4 V or exceeds 1.3 V when the output is not activated.


Check the wiring

Faults in the control module's female connector could be the cause of the diagnostic trouble code. Check the connector for oxidation, dislodged pins and pin clamping force.

Jiggle the wiring harness at several points and in different directions to detect intermittent breaks and short circuits in the wiring harness. Monitor the multimeter, the diagnostic tool or test lamp during the check. In addition, check contacts, connectors and crimp connections for oxidation, dislodged pins and pin clamping force.

For more information see also:

- The "Read Values" menu for a description of read values.

- The "Activations" menu for a description of application areas.