B2410
Read the instructions below then
start the fault diagnostic procedure.
Symptom: The cabin is misting up again.
Bad air in the cabin.
Perceived temperature in cabin too high compared to the set temperature.
Recirculation Motor. Short to B+
Recirculation Motor. Open Circuit / Short to Ground
Fault symptoms
•
|
The cabin is misting up again.
|
•
|
Perceived temperature in cabin too high compared to the set temperature.
|
Conditions
The following conditions apply:
•
|
Short circuit to B+ is indicated when the output for the recirculation motor is not activated and the voltage exceeds 2.5 V.
|
•
|
Short circuit to ground and open circuit are indicated when the output for the recirculation motor is not activated and the voltage is below 0.1 V.
|
•
|
The diagnostic trouble code is deleted after the ignition has been switched on 20 times if the malfunction conditions have not been fulfilled.
|
•
|
When the diagnostic trouble code is generated the output is switched off.
|