Poor cooling
Read the instructions below then 
start the fault diagnostic procedure.
Symptom: The compressor clutch engages but the system's cooling capacity is insufficient.
 
  
 
 
  
  
  
    
  
  
  
   Fault symptoms
  
  
   The compressor clutch engages but the system's cooling capacity is insufficient.
   
   
   
    Conditions
   
  
  
   The conditions are as follows:
   
   
  
  
  
   
    
     
      | • | Outside temperature >5°C. 
 
 | 
    
   
  
  
   
    
     
      | • | Radiator fans are functioning. 
 
 | 
    
   
  
  
   
    
     
      | • | There is free air flow to the condensers. 
 
 | 
    
   
  
  
   
    
     
      | • | No difference in temperature between the drier filter inlet and outlet. 
 
 | 
    
   
  
  
   
    
     
      | • | Pressure at the low-pressure side normally 1.5-2.5 bar. 
 
 | 
    
   
  
  
   
    
     
      | • | Pressure at the high-pressure side depends on the load on the system. 
 
 |