B0478
Read the instructions below then start the fault diagnostic procedure.
Symptom: Poor heating of cabin Heater switched off but allowed to restart
B0478 |
Fault symptoms
Poor heating of cabinHeater switched off but allowed to restart
Conditions
Heater running.The control module checks the temperature of the combustion chamber when the heater is running. If the flame temperature sensor registers a temperature below 105°C (221°F) (resistance of flame temperature <1403 Ohm) for approximately 3 minutes when the heater is running at low power, a DTC is generated.
Diagnostic help
The temperature from the flame temperature sensor can be read using the diagnostic tool.The heater has an extra cable and connector that is separate from the ordinary wiring on the heater. This cable and connector are not used but are connected to the control module. Therefore, check that this cable is undamaged before starting fault diagnosis.
The ordinary wiring between the heater and the 8-pin connector contains an additional light-green wire that is cut and not used.