SAAB WIS ONLINE

P1640

Read the instructions below then start the fault diagnostic procedure.

Symptom: Engine fails to start. CHECK ENGINE. Misfiring can occur before trouble code is generated.

P1640


Main Relay Circuit. No Voltage to Control Module pin 1.


Fault symptoms


Engine fails to start.

CHECK ENGINE.

Misfiring can occur before trouble code is generated.


On-Board Diagnostics

Type of diagnosis:


- Continuous. But interrupted when fault criteria fulfilled and will not restart until next driving cycle.


Enable criteria:


- Ignition ON


Fault criteria:


- Main relay voltage below 3 V for 1 s.


Dependents:


- None.


System reaction to a fault:


- None.


OK report:


- Enable criteria fulfilled and fault criteria not fulfilled within 60 s.


Fault handling: (See section Fault handling III, other emission-related components and functions for more information.)


- Type III.


Diagnostic help

Fault diagnosis concerns electrical fault in connecting leads or in the relay.

Functions in the diagnostic tool related to the fault:


Main relay voltage, in V.


See also description of read value under "Read Values" menu for more information.

Check the wiring