P1640
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Engine fails to start.
CHECK ENGINE.
Misfiring can occur before trouble code is generated.
Main Relay Circuit. No Voltage to Control Module pin 1.
Fault symptoms
•
|
Misfiring can occur before trouble code is generated.
|
On-Board Diagnostics
Type of diagnosis:
-
|
Continuous. But interrupted when fault criteria fulfilled and will not restart until next driving cycle.
|
Enable criteria:
Fault criteria:
-
|
Main relay voltage below 3 V for 1 s.
|
Dependents:
System reaction to a fault:
OK report:
-
|
Enable criteria fulfilled and fault criteria not fulfilled within 60 s.
|
Fault handling:
(See section
Fault handling III, other emission-related components and functions
for more information.)
Diagnostic help
Fault diagnosis concerns electrical fault in connecting leads or in the relay.
Functions in the diagnostic tool related to the fault:
•
|
Main relay voltage, in V.
|
See also description of read value under
"Read Values" menu
for more information.
Check the wiring