Draining and filling of refrigerant
 
  
 
 
  
   
    
     |  | Draining and filling of refrigerant | 
   
  
  
   
   
   
   
    
     
      
       | 
         
          
           | 
             
              
               |  Warning |  
               | 
                 
                  
                   | 
                     Read through the following safety regulations before you start working on the A/C system.
                     |  
                   | • | Wear protective glasses and impermeable gloves, since there is a risk of burn and frost injuries. 
 
 |  
                   | • | If the skin comes into contact with the refrigerant, the exposed areas should be bathed in cold water and treated like a burn. 
 
 |  
                   | • | Should the coolant get into the eyes, they must be rinsed thoroughly with water for at least 10 minutes. 
 
 |  
                   | • | Refrigerant must not intentionally be released into the atmosphere. If, however, the refrigerant is unintentionally released in the premises, open and ventilate well before continuing work. 
 
 |  
                   | • | Gases that are formed when heating a refrigerant are a health hazard and can have a serious effect on the lungs. 
 
 |  
                   | • | Work should commence as soon as possible after emptying the A/C system as residual oil may emit refrigerant vapour that could collect and leak out if the work is delayed. 
 
 |  
                   | • | Smoking and open flames must not occur when handling refrigerants. 
 
 |  
                   | • | Refrigerant containers must not be exposed to heating, because the pressure will then increase resulting in the risk of explosion. 
 
 |  |  
               |  |  |  | 
     
    
    
   
   
    For information about the equipment, consult the manufacturer's manuals.
    
    
    
    
    
    
    
   
   
    
   
   
   
    
     
      
       | 1. | Remove the protective covers for the service valves on the high and low pressure pipes. 
 
 | 
     
    
   
   
    
     
      
       | 2. | Connect the blue hose to the low pressure pipe. Connect the red hose to the high pressure pipe. 
 
 | 
     
    
   
   
    
     
      
       | 3. | The snap-on couplings are shaped like so-called "Schrader valves" and the connection therefore takes place in two stages: 
 
 | 
     
    
   
   
    
     
      
       |  | • | Fit the snap-on coupling to the service connection. 
 
 | 
     
    
   
   
    
     
      
       |  | • | Turn the knob clockwise to open the valve and let the refrigerant pass through the connection. 
 
 | 
     
    
   
   
    
     
      
       | 4. | Start draining the system. Follow the instructions for each respective machine. Note the quantity of drained compressor oil. 
 
 | 
     
    
   
   
    
     
      
       | 5. | Turn off the cocks and disconnect from the machine. 
 
 | 
     
    
   
   
    
     
      
       | 6. | Fit the protective covers for the service valves in the high and low pressure pipes. 
 
 | 
     
    
   
   
   
   
   
   
   
   
    
   
   
   
    
     
      
       | 1. | Remove the protective covers for the service valves from the high and low pressure pipes. 
 
 | 
     
    
   
   
    
     
      
       | 2. | Connect the blue hose to the low pressure pipe. Connect the red hose to the high pressure pipe. 
 
 | 
     
    
   
   
    
     
      
       | 3. | The snap-on couplings are shaped like so-called "Schrader valves" and the connection therefore takes place in two stages: 
 
 | 
     
    
   
   
    
     
      
       |  | • | Fit the snap-on coupling to the service connection. 
 
 | 
     
    
   
   
    
     
      
       |  | • | Turn the knob clockwise to open the valve and let the refrigerant pass through the connection. 
 
 | 
     
    
   
   
    
   
   
    
     
      
       | 5. | For fully automatic filling
        
        : Fill with compressor oil and tracing agent in accordance with the machine's instructions. 
 
 | 
     
    
   
   
    
     
      
       | 6. | Start filling the system. Follow the instructions for each respective machine. 
 
 | 
     
    
   
   
    
     
      
       | 7. | Turn off the cocks and disconnect from the machine. 
 
 | 
     
    
   
   
    
     
      
       | 8. | Fit the service valves on the high and low pressure pipes. 
 
 |