Valve housing
| Valve housing |
| To remove |
| Important | ||
|
Automatic transmission up to and including 02GV 706486 : The wiring harness must also be changed when changing the valve housing so it suits the new one. |
||
| 1. |
Remove the
Valve housing cover
|
|
| 2. |
Unplug the solenoids and temperature sensor.
|
|
| 3. |
Slacken the bolts with 10 mm heads securing the valve housing.
|
||||||||||||||||
| 4. |
Carefully detach the manual valve from the selector lever out of the retaining eye and carefully lift out the valve housing.
|
|||||||
| Fitting |
| Important | ||
|
Automatic transmission up to and including 02GV 706486 : The wiring harness must also be changed when changing the valve housing so it suits the new one. |
||
| 1. |
Lift the valve housing into position.
|
|||||||
| 2. |
Fit the valve housing.
Tightening torque 7 Nm (5 lbf ft)
|
|||||||
| 3. |
Plug in the solenoids and fit the temperature sensor.
|
|
| 4. |
Fit the
valve housing cover
.
|
|
| 5. |
After valve housing replacement: carry out
Adaptation, resetting
.
|
|