Blended-air temperature sensor, LH
Blended-air temperature sensor, LH |
1. |
Remove the data link connector, 2 screws, and detach the leads to the floor lighting.
|
2. |
Remove the lower part of the panel from the driver's side, 3 screws.
|
3. |
Pull the sensor (A) from the air duct, which leads to the lower part of the panel, by releasing the clips and sliding it out
|
4. |
Remove the radio section (A) and the ACC control panel (B).
|
5. |
Unplug the upper connector (A) (black) from the heating and ventilation unit.
|
6. |
Withdraw the pins in question from the connector (B).
|
7. |
Pull out the sensor (C).
|
Note | ||
The leads in question are taped to a wiring harness. Facilitate removal by clipping the appropriate leads in a suitable spot and wire with new leads during fitting. |
To fit |
1. |
Insert new cables (B).
|
2. |
Refit the connector in the upper bracket for the heating and ventilation unit (A).
|
3. |
Refit the sensor to the lower part of the panel (A).
|
4. |
Fit the radio section (A) and the ACC control panel (B).
|
5. |
Refit the cables for the floor lighting and fit the data link connector, 2 screws.
|
6. |
Fit the lower part of the panel on the driver's side, 3 screws.
|
Note | ||
New leads must be routed when refitting. Fasten the new leads to the original wiring harness. |