B1345

Read the instructions below then start the fault diagnostic procedure.

Symptom: Perceived temperature in cabin too high or too low compared to the set temperature.

B1345


Mixed Air Sensor Left. Short to Ground

Mixed Air Sensor Left. Open Circuit / Short to B+


Fault symptoms

Perceived temperature in cabin too high or too low compared to the set temperature.

Conditions

The following conditions apply:


• Ignition ON

• Open circuit or short circuit to B+ is generated when the voltage on pin 24 is >4.9 V.

• Short circuit to ground on pin is generated when the voltage on pin 24 is <0.1 V.

• Measured every 40 ms, and 5 consecutive measurements are required to generate a diagnostic trouble code.

• The diagnostic trouble code is deleted after the ignition has been switched on 20 times if the malfunction conditions have not been fulfilled.

• When the diagnostic trouble code is generated the control module uses one substitute value.