SAAB WIS ONLINE

B2296

Read the instructions below then start the fault diagnostic procedure.

Symptom: Experienced temperature is too low compared to the set temperature. The cabin temperature cannot be adjusted on the right side.

B2296


Heater Flap Motor Right. Flap Jammed. Note: May set if not calibrated.





Fault symptoms

Experienced temperature is too low compared to the set temperature. The cabin temperature cannot be adjusted on the right side.

Conditions

The following conditions apply:


When the stepping motor operates in the range 10-90 % of its total range (which is 0-100 %), the control module senses if the power consumption is above a certain value, and if this is the case, sets the diagnostic trouble code for jammed flap.

The diagnostic trouble code can be set if the control module has not been calibrated.

Continuous monitoring and when calibrating.