B2375
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Perceived temperature in cabin too high or too low compared to the set temperature.
Heat Exchanger Solenoid. Short to B+
Heat Exchanger Solenoid. Open Circuit / Short to Ground
Fault symptoms
Perceived temperature in cabin too high or too low compared to the set temperature.
Conditions
The following conditions apply:
•
|
Short circuit to B+ is indicated when the output for the heat exchanger solenoid is not activated and the voltage on pin 14 is B+.
|
•
|
Short circuit to ground is indicated when the output for the heat exchanger solenoid is activated and the voltage on pin 14 is lower than 1V.
|
•
|
The diagnostic trouble code is deleted after the ignition has been switched on 20 times if the malfunction conditions have not been fulfilled.
|
•
|
When the diagnostic trouble code is generated the output is switched off.
|