B2380

Read the instructions below then start the fault diagnostic procedure.

Symptom: Perceived temperature in cabin too low compared to the set temperature.

B2380


Circulation Pump. Short to B+

Circulation Pump. Open Circuit / Short to Ground


Fault symptoms

Perceived temperature in cabin too low compared to the set temperature.

Conditions

The following conditions apply:


• Ignition ON

• Short circuit to B+ indicated when the output for the circulation pump is activated and the voltage on pin 15 exceeds 6 V.

• Short circuit to ground is indicated when the output for the circulation pump is not activated and the voltage on pin 15 exceeds 6 V.

• Measured every 50 ms.

• The diagnostic trouble code is deleted after the ignition has been switched on 20 times if the malfunction conditions have not been fulfilled.

• When the diagnostic trouble code is generated the output is switched off.