Read the instructions below then start the fault diagnostic procedure.

Symptom: The cabin is misting up again. Bad air in the cabin. Perceived temperature in cabin too high compared to the set temperature.

B2410


Recirculation Motor. Short to B+

Recirculation Motor. Open Circuit / Short to Ground


Fault symptoms


• The cabin is misting up again.

• Bad air in the cabin.

• Perceived temperature in cabin too high compared to the set temperature.


Conditions

The following conditions apply:


• Ignition ON.

• Short circuit to B+ is indicated when the output for the recirculation motor is not activated and the voltage exceeds 2.5 V.

• Short circuit to ground and open circuit are indicated when the output for the recirculation motor is not activated and the voltage is below 0.1 V.

• The diagnostic trouble code is deleted after the ignition has been switched on 20 times if the malfunction conditions have not been fulfilled.

• When the diagnostic trouble code is generated the output is switched off.