Read the instructions below then start the fault diagnostic procedure.

Symptom: CHECK ENGINE lamp on.

P0112


Intake Air Temperature Sensor Circuit. Short to Ground.

Fault symptoms


CHECK ENGINE lamp on.


On-Board Diagnostics

Type of diagnosis:


- Continuous.


Enable criteria:


- Turn Ignition On.


Fault criteria:


- When the voltage on the input is less than 0.05 V for more than 0.5 seconds.


System reaction to a fault:


- The control module uses 40°C as a substitute value.


OK report:


- Enable criteria fulfilled without any faults being reported.


Check the wiring

A fault in the control module's female connector can generate a DTC. Check the contact for oxidation, dislodge pins and pin clamping force.

Jiggle the leads and in-line connectors at various points and in different directions to detect any intermittent breaks or short circuits in the wiring. Observe the multimeter, test lamp or diagnostic tool while doing this. Check switches, connectors and crimp connections for oxidation, dislodged pins and pin clamping force.

For more information, see also:

- "Read Values" menu for a description of read values.