P0262
Read the instructions below then start the fault diagnostic procedure.
Symptom: CHECK ENGINE lamp on. Engine turns off.
P0262 |
Injector 2 Circuit, Open/Short
Fault symptoms
• |
CHECK ENGINE lamp on.
|
• |
Engine turns off.
|
On-Board Diagnostics
Fault criteria:
- |
Power amp diagnosis in the control module (short to ground/voltage or open circuit)
|
System reaction to a fault:
- |
The defective valve does not deactivate. The other valves operate normally.
|
For more information, see also:
- "Read Values" menu for a description of read values.
- "Activate" menu for a description of applications.