P1137
Read the instructions below then
start the fault diagnostic procedure.
Symptom: CHECK ENGINE.
O2S Circuit. Low Voltage. Sensor 2.
Fault symptoms
On-Board Diagnostics
Type of diagnosis:
-
|
Continuous. Terminated when fault criteria fulfilled. Restarts next driving cycle.
|
Enable criteria:
-
|
Engine load over 150 mg/c. Coolant temperature more than 60°C. Preheating active longer than 4s. Preheating current exceeds 300 mA. Closed loop active longer than 5s. Closed loop between 20 and -20%. No fuel shut-off.
|
Fault criteria:
-
|
O2S2 voltage is between 0.05 and 0.3V for longer than 90s.
|
Dependents:
System reaction to a fault:
-
|
Transition adaptation of closed loop is blocked.
|
OK report:
-
|
Enable criteria fulfilled and 120s has expired without a fault report.
|
Fault handling:
(For more information, see
Fault handling III, other emission-related components and functions
.)
Diagnostic help
Fault diagnosis concerns an electrical fault in connecting leads or in the sensor.
Functions in the diagnostic tool related to the fault:
•
|
Diagnostic status for the diagnosis.
|
•
|
Oxygen Sensor Value, unit V.
|
For more information, see
Menu "Read Values"
.
Note
|
Oxygen sensor receives reference oxygen from the surrounding air via the connecting cables. For this reason, electrical contact spray or grease
must not
be used on the oxygen sensor connector.
|
Checking the wiring