SAAB WIS ONLINE

Boost pressure control valve (179a), EDC16

Boost pressure control valve (179a), EDC16

Location

Solenoid valve, charge air (179a)

Main task

Controls negative pressure to the turbocharger wastegate

Type

Solenoid valve.


Connection

Pin no. Signal type Description
1

Power supply

Connected to fuse 14 on the instrument panel fuse board.

2

Operation

The solenoid valve is grounded from ECM pin 7(B) via a PWM signal.