Coolant level sensor

Coolant level sensor




General

The coolant level sensor consists of a round magnetic float which moves up and down along a hollow column attached to the bottom of the expansion tank. The sensor sits in the hollow column on the ambient of the tank and is affected by the magnet.

The SID control module sends B+ to the level sensor via pin 28, and the sensor is grounded to grounding point G40/42. At normal level, the float arm is level with the switch, the magnet in the float arm closes the circuit and pin 28 of the SID is grounded. At low levels, the circuit to ground is broken.

The function initiates a CHECK message on the main instrument unit information display (30 seconds delay).

Diagnosis

If there is a break in the coolant level sensor circuit “Coolant level low. Refill.” is displayed despite the coolant level being correct.

If a short-circuit to ground occurs, the CHECK message will not be shown even if the coolant level is low.

The SID control module will not generate a diagnostic trouble code.