(383-2572) Modified anti-theft alarm configuration
Symptom: If the incorrect parameters are selected, the message "ALARM FAILURE, CONTACT WORKSHOP" in SID.
The following DTCs could occur in TWICE: B1785, B1790, B1795 or B1890.
TECHNICAL SERVICE BULLETIN
|
Bulletin Nbr:
|
383-2572
|
Date:
...........
|
JuliĀ 2005
|
Market:
|
US/CA
|
|
Modified anti-theft alarm configuration
|
This bulletin describes spare parts programming in TWICE in order to prevent faults in the anti-theft alarm system.
Saab 9-5 M04- with anti-theft alarm
The glass breakage sensor that was previously part of the anti-theft alarm system has been eliminated from model year 04. During the course of M04 (from VIN 43013120), the alarm siren has been replaced by the standard car horn.
During spare parts programming or adjustment of TWICE, it is important to select the correct parameters for the anti-theft alarm's configuration in order to prevent faults in the anti-theft alarm system.
Symptom description
If the incorrect parameters are selected, the message "ALARM FAILURE, CONTACT WORKSHOP" in SID.
The following DTCs could occur in TWICE: B1785, B1790, B1795 or B1890.
Note
|
The fault symptom first arises when the anti-theft alarm has been armed by locking with the remote control.
|
The following selections for anti-theft protection should be selected in Tech2 during spare parts programming of TWICE:
M04 up to VIN 43013119
Parameter
|
Select Option
|
Anti-theft alarm:
|
With
|
Alarm, acoustic indicator:
|
With siren sound
|
Alarm, glass breakage sensor:
|
Without
|
Tilt sensor:
|
Without
|
From VIN 43013120
Parameter
|
Select Option
|
Anti-theft alarm:
|
With
|
Alarm, acoustic indicator:
|
Without siren sound
|
Alarm, glass breakage sensor:
|
Without
|
Tilt sensor:
|
Without
|
Warranty/Time Information
|