B1340
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Perceived temperature in cabin too high or too low compared to the set temperature.
Solar Sensor. Open Circuit / Communication Fault
Fault symptoms
Perceived temperature in cabin too high or too low compared to the set temperature.
Conditions
The following conditions apply:
•
|
Open circuit or communication fault.
|
•
|
The solar sensor continuously sends an identification pulse 5V-0V-5V. The control module continuously searches for identification pulses.
|
•
|
The diagnostic trouble code is deleted after the ignition has been switched on 20 times if the malfunction conditions have not been fulfilled.
|
•
|
When the diagnostic trouble code is generated the control module use a substitute value.
|