B2410

Read the instructions below then start the fault diagnostic procedure.

Symptom: The cabin is misting up again. Bad air in the cabin. Perceived temperature in cabin too high compared to the set temperature.

B2410


Recirculation Motor. Short to B+

Recirculation Motor. Open Circuit / Short to Ground


Fault symptoms


The cabin is misting up again.

Bad air in the cabin.

Perceived temperature in cabin too high compared to the set temperature.


Conditions

The following conditions apply:


Ignition ON.

Short circuit to B+ is indicated when the output for the recirculation motor is not activated and the voltage exceeds 2.5 V.

Short circuit to ground and open circuit are indicated when the output for the recirculation motor is not activated and the voltage is below 0.1 V.

The diagnostic trouble code is deleted after the ignition has been switched on 20 times if the malfunction conditions have not been fulfilled.

When the diagnostic trouble code is generated the output is switched off.