Power Brake Booster Pump Installation
| Power Brake Booster Pump Installation |
Special Tools
EN 45059 Angle Sensor| 1. |
Install the power brake booster pump gasket.
|
|
| 2. |
Install the power brake booster pump (2).
|
|
| 3. |
Refer to
Fastener Caution
.
Install the 4 NEW power brake booster pump bolts (1) and tighten in 2 passes:. |
|
| • |
First pass in sequence to
5 Nm(45 lb in)
.
|
| • |
Second pass to
50 °
using the
EN 45059
angle sensor
|