Thermostat Diagnosis
| Thermostat Diagnosis | 
| Thermostat Test Procedure Using Glycol | 
Inspect the operation of the thermostat by hanging the thermostat on a hook in a 33 percent glycol solution.
In order to inspect if the thermostat valve is opening properly, perform the following test:
 
    
    | 1. | Completely submerge the thermostat in a glycol solution. The solution should be 11°C (22°F) above the temperature indicated on the thermostat valve. | |
| 2. | Thoroughly agitate the solution. Under these conditions, the thermostat valve should open. | |
In order to inspect if the thermostat valve is closing properly, perform the following test:
| 1. | Completely submerge the thermostat in a glycol solution. The solution should be 6°C (10°F) below the temperature indicated on the thermostat valve. | |
| 2. | Thoroughly agitate the solution. Under these conditions, the thermostat valve should close completely. | |

 
		