AFL/EPC Connectors
AFL/EPC Connectors |
Special Tools
For equivalent regional tools, refer to Special Tools .Removal Procedure |
Follow the steps below in order to remove terminals from the connector.
1. |
For connectors with a bolt in the dress cover, turn the bolt counterclockwise to remove the connector from the component.
|
2. |
Locate the connector position assurance (CPA) on the top of the wire dress cover. Slide the CPA forward.
|
3. |
Slide the lever lock forward while pressing down on the lever lock release tab.
|
4. |
View showing depressing of the lever lock release tab.
|
5. |
View of connector in released position.
|
6. |
Disconnect the connector from the component.
|
7. |
Locate the dress cover locking tabs at the corners of the dress cover. Use a small flat-blade tool to release the locking tabs and remove the dress cover.
|
8. |
Release the rear lower half of the wiredress cover.
|
9. |
Release the tabs that are holding the wiredress cover to the connector body.
|
11. |
Use the EL-38125-12A tool to release the terminals by lifting the terminal retaining tabs on the inside of the connector.
|
12. |
While holding the removal tool in place, gently pull the wire out of the back of the connector. Always remember never use force when pulling a terminal out of a connector.
|
Repair Procedure |
Use the appropriate terminal / terminated lead.