Basic Digital Multimeter Requirements
|
Basic Digital Multimeter Requirements
|
Digital Multimeter (DMM) Basic Requirements
|
Service information is validated using digital multimeters that meet or exceed the following requirements. Using a multimeter that does not meet these basic requirements may give inaccurate readings which could lead to an incorrect diagnosis.
Display and Settings
2.
|
Voltage, amperage, resistance, frequency, diode test settings, and min-max function
|
3.
|
Display positive and negative values
|
Voltage
1.
|
Have at least 10 MΩ input impedance
|
2.
|
Test a DC voltage range of 0.1-1000 V.
|
3.
|
Test an AC voltage range of 0.1-1000 V.
|
Amperage
1.
|
Test a DC amperage range of 0.1µA-10 A.
|
2.
|
Test an AC amperage range of 0.1µA-10 A.
|
Resistance
Test a resistance range of 0.1 Ω-40 MΩ and displays infinite for a value greater than 40 MΩ (O.L. (Over-load))
Frequency
Test for a frequency range of 0.5 HZ-199 K HZ
Diode Test
1.
|
Apply at least 1 mA when performing the diode bias test
|
2.
|
Display the break over voltage drop (0-3 V) of a forward biased diode
|
3.
|
Display infinite (O.L. (Over-load)) when a diode is reverse biased
|
Min-Max Readings
1.
|
Can update at a 1 ms sample rate
|
2.
|
Saves and displays minimum and maximum values
|