Delphi Connectors (Push To Seat)
|
Delphi Connectors (Push To Seat)
|
Special Tools
For equivalent regional tools, refer to
Special Tools
.
Follow the steps below in order to repair push to seat connectors.
1.
|
Remove the terminal position assurance (TPA) device, the connector position assurance (CPA) device, and/or the secondary lock.
|
2.
|
Separate the connector halves (1).
|
3.
|
Use the proper pick or removal tool (1) in order to release the terminal.
|
4.
|
Gently pull the cable and the terminal (2) out of the back of the connector.
|
5.
|
Re-form the locking device if you are going to reuse the terminal (1).
|
6.
|
To repair the terminal, refer to Terminal Repair.
|
1.
|
In order to reuse a terminal or lead assembly, refer to
Wiring Repairs
.
|
2.
|
Ensure that the cable seal is kept on the terminal side of the splice.
|
3.
|
Insert the lead from the back until it catches.
|
4.
|
Install the TPA, CPA, and/or the secondary locks.
|
2.
|
Find the appropriate terminated lead.
|
3.
|
Use the appropriate splice sleeves depending on the gauge size.
|