FCI Connectors (Lever Lock)
FCI Connectors (Lever Lock) |
Special Tools
For equivalent regional tools, refer to Special Tools .Removal Procedure |
Follow the steps below in order to remove terminals from the connector.
1. |
Slide the lever lock forward while pressing down on the lever lock release tab.
|
2. |
The release tab is located on the top of the wiredress cover.
|
3. |
View of connector in released position.
|
4. |
Disconnect the connector from the component.
|
5. |
Locate the dress cover locking tabs at the corners of the dress cover. Use a small flat-blade tool to release the locking tabs and remove the dress cover.
|
7. |
While holding the removal tool in place, gently pull the wire out of the back of the connector. Always remember never use force when pulling a terminal out of a connector.
|
Terminated Lead Repair |
1. |
Remove the terminal.
|
2. |
Find the appropriate terminated lead.
|
3. |
Use the appropriate splice sleeves depending on the gauge size.
|
4. |
Refer to
Splicing Copper Wire Using Splice Sleeves
|