Kostal Connectors (Glow Plug Control Module)
Kostal Connectors (Glow Plug Control Module) |
View of connector in released position.
1. |
Locate the assist lever at the back of the connector. Move the assist lever to the rear position.
|
2. |
Disconnect the connector from the component.
|
3. |
Use a small flat-blade tool to remove the dress cover.
|
4. |
Slide the dress cover forward and off of the connector.
|
5. |
The terminal positive assurance (TPA) is located in the front and rear of the connector.
|
6. |
Use a small flat-blade tool to move the front TPA to the preset position, outboard approximately 0.125 in. (3 mm). |
7. |
Use a small flat-blade tool to completely remove the rear TPA from the connector.
|
8. |
Use the EL-38125-24 or the EL-38125-560 tool to release the terminals by inserting the tool into the terminal release cavity.
|
9. |
While holding the removal tool in place, gently pull the wire out of the back of the connector. Always remember never use force when pulling a terminal out of a connector.
|
Terminated Lead Repair |
1. |
Remove the terminal.
|
2. |
Find the appropriate terminated lead.
|
3. |
Use the appropriate splice sleeves depending on the gauge size.
|
4. |
Refer to
Splicing Copper Wire Using Splice Sleeves
|