Tyco/AMP Connectors (0.25 Cap)
Tyco/AMP Connectors (0.25 Cap) |
Special Tools
For equivalent regional tools, refer to Special Tools .Terminal Removal Procedure |
1. |
Disconnect the connector from the component by pressing down on the connector position assurance (CPA).
|
3. |
Repeat the process for the other side of the connector.
|
4. |
Ensure that the TPA is in the proper position to remove the terminals.
|
5. |
While pushing the terminal forward, insert the EL-38125-24 in the release cavity above the terminal you are removing, gently pull the wire out of the back of the connector. Always remember never use force when pulling a terminal out of a connector.
|
Terminated Lead Repair |
1. |
Remove the terminal.
|
2. |
Find the appropriate terminated lead.
|
3. |
Use the appropriate splice sleeves depending on the gauge size.
|
4. |
Refer to
Splicing Copper Wire Using Splice Sleeves
|