Tyco/AMP Connectors (Door Module)
|
Tyco/AMP Connectors (Door Module)
|
Special Tools
For equivalent regional tools, refer to
Special Tools
.
Side view of connector.
View of top of connector.
1.
|
Locate the assist lever and lock on the top of the connector.
|
2.
|
While depressing the lock, pull the lever over and past the lock.
|
3.
|
Disconnect the connector from the component.
|
4.
|
Locate the dress cover locking tabs at the rear of the connector. Use a small flat-blade tool to release the locking tabs. Repeat this procedure for the other locking tab.
|
5.
|
Once the locking tabs are unlocked, slide the inner connector out of the rear of the connector housing.
|
6.
|
Use the EL-38125-12A tool to release the terminals by pressing on the tang.
|
7.
|
While holding the removal tool in place, gently pull the wire out of the back of the connector. Always remember never use force when pulling a terminal out of a connector.
|
2.
|
Find the appropriate terminated lead.
|
3.
|
Use the appropriate splice sleeves depending on the gauge size.
|