SAAB WIS ONLINE

Yazaki Connectors (16-Way)

Yazaki Connectors (16-Way)


Special Tools

For equivalent regional tools, refer to Special Tools .

Removal Procedure


1. While depressing the lock, pull the two connector halves apart.


2.
Note

The TPA is fragile and may break if not done carefully.


Use a small flat-blade tool to very carefully push the terminal position assurance (TPA) towards the face of the connector on both sides of the connector.

3. View of the male half of the connector with female terminals.


4. View of the female half of the connector with male terminals.


5. Use the EL 38125-215 tool to release the terminals by inserting the tool into the terminal release cavity.

6. View of the female half of the connector with male terminals.


7. View of the male half of the connector with female terminals.


8. While holding the removal tool in place, gently pull the wire out of the back of the connector. Always remember never use force when pulling a terminal out of a connector.


Terminated Lead Repair


1. Remove the terminal.

2. Find the appropriate terminated lead.

3. Use the appropriate splice sleeves depending on the gauge size.

4. Refer to Splicing Copper Wire Using Splice Sleeves