Oil Pump Cleaning and Inspection
| Oil Pump Cleaning and Inspection |
| 1. |
Remove the external rotor with the internal rotor.
|
|
| 2. |
Visually inspect the components.
|
|
| 3. |
Install the external and the internal rotors.
|
|
| 4. |
Inspect the axial clearance of the rotors in respect to the control unit housing upper edge.
SpecificationsPermissible measurement is 0.02-0.058 mm (0.00079-0.00228 in). |
|