Heated Oxygen Sensor Replacement (LBS/A20DTH)
|
Heated Oxygen Sensor Replacement (LBS/A20DTH)
|
Callout
|
Component Name
|
1
|
Heated Oxygen Sensor
Warning
|
The exhaust temperature sensor and exhaust pressure differential sensor line fittings may be difficult to remove when the engine exhaust system temperature is below 48°C (120°F). Excessive force may damage the threads in the exhaust manifold or exhaust pipe.
|
|
|
|
|
Refer to
Fastener Caution
.
Procedure
1.
|
Release the sensor electrical connector.
|
2.
|
Remove the heated oxygen sensor fastener.
|
3.
|
Remove the heated oxygen sensor fastener using
EN-8396350
remover/installer.
|
Tighten
45 Nm (33 lb ft)
Special Tools
EN-8396350
Remover/Installer Oxygen Sensor
For equivalent regional tools, refer to
Special Tools
.
|