Heated Oxygen Sensor Replacement (LBS/A20DTH)
 
  
 
 
  
   
    
     |  | Heated Oxygen Sensor Replacement (LBS/A20DTH) | 
   
  
  
  
   
    
    
   
   
    
     | Callout | Component Name | 
    
     | 1 
 
 | Heated Oxygen Sensor 
 
 
        
         
          | 
            
             
              | 
                
                 
                  |  Warning |  
                  | 
                    
                     
                      | 
                        The exhaust temperature sensor and exhaust pressure differential sensor line fittings may be difficult to remove when the engine exhaust system temperature is below 48°C (120°F). Excessive force may damage the threads in the exhaust manifold or exhaust pipe.
                        |  |  
                  |  |  |  |  Refer to
         
          Fastener Caution
         
         .
 
 
 
 
       Procedure
      
        
         
          | 1. | Release the sensor electrical connector. 
 
 |  
        
         
          | 2. | Remove the heated oxygen sensor fastener. 
 
 |  
        
         
          | 3. | Remove the heated oxygen sensor fastener using
           
            EN-8396350
           
           remover/installer. 
 
 |  
 
        Tighten
       45 Nm (33 lb ft)
 
 
        Special Tools
       EN-8396350
        
        Remover/Installer Oxygen Sensor
 For equivalent regional tools, refer to
       
        Special Tools
       
       .
 
 
 |