DTC P0671, P0672, P0673, or P0674
|
DTC P0671, P0672, P0673, or P0674
|
DTC P0671 00
Cylinder 1 Glow Plug Control Circuit Malfunction
DTC P0672 00
Cylinder 2 Glow Plug Control Circuit Malfunction
DTC P0673 00
Cylinder 3 Glow Plug Control Circuit Malfunction
DTC P0674 00
Cylinder 4 Glow Plug Control Circuit Malfunction
Circuit/System Description
|
This DTC applies to internal microprocessor integrity conditions within the glow plug control module.
Conditions for Running the DTC
|
•
|
The battery voltage is between 9-16 V.
|
•
|
The DTC runs once per ignition cycle when the above condition is met.
|
Conditions for Setting the DTC
|
The ECM detects a glow plug control module malfunction.
Action Taken When the DTC Sets
|
DTC P0671, P0672, P0673 and P0674 are Type C DTC.
Conditions for Clearing the DTC
|
DTC P0671, P0672, P0673 and P0674 are Type C DTC.
Schematic Reference
Engine Controls Schematics
Connector End View Reference
Component Connector End Views
Electrical Information Reference
DTC Type Reference
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Scan Tool Reference
Control Module References
for scan tool information
Circuit/System Verification
|
Operate the vehicle within the conditions for running the DTC to verify the DTC does not reset. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records data.
1.
|
Ignition OFF, disconnect the harness connector at the K34 Glow Plug Control Module.
|
2.
|
Test for less than 5 Ω of resistance between the ground circuit terminal 3 and ground.
|
3.
|
If greater than the specified range, test the ground circuit for an open/high resistance.
|
4.
|
Test for greater than 0.3 Ω of resistance between each of the glow plug circuit terminals and ground.
|
|
•
|
Glow Plug 1 circuit terminal 3
|
|
•
|
Glow Plug 2 circuit terminal 1
|
|
•
|
Glow Plug 3 circuit terminal 4
|
|
•
|
Glow Plug 4 circuit terminal 6
|
5.
|
If less than the specified range, test the glow plug circuit for a short to ground.
|
6.
|
Ignition ON, verify a test lamp illuminates between the ignition voltage circuit terminal 4 and ground.
|
7.
|
If the test lamp does not illuminate, test the ignition voltage circuit for a short to ground or an open/high resistance.
|
8.
|
If all circuits test normal, replace the K34 Glow Plug Control Module.
|