Tyco/AMP Connectors (0.25 Cap)
| Tyco/AMP Connectors (0.25 Cap) | 
Special Tools
| • | EL-38125-580
        
        Terminal Release Tool Kit | |
| • | J-38125-24
        
        Terminal Release Tool | |
For equivalent regional tools, refer to Special Tools .
| Terminal Removal Procedure | 
| 1. | Disconnect the connector from the component by pressing down on the connector position assurance (CPA). | |
| 3. | Repeat the process for the other side of the connector. | |
| 4. | Ensure that the TPA is in the proper position to remove the terminals.   | |
| 5. | While pushing the terminal forward, insert the J-38125-24 in the release cavity above the terminal you are removing, gently pull the wire out of the back of the connector. Always remember never use force when pulling a terminal out of a connector.   | |
| 6. | Repair the terminal by following the
        
         Repairing Connector Terminals
        
        procedure. | |
| 7. | Insert the repaired terminal back into the cavity. Repeat the diagnostic procedure to verify the repair and reconnect the connector bodies. | |

 
         
		