Yazaki Connectors (16-Way)
Yazaki Connectors (16-Way) |
Special Tools
• |
EL-38125-580
Terminal Release Tool Kit
|
• |
J-38125-215
Terminal Release Tool
|
For equivalent regional tools, refer to Special Tools .
Terminal Removal Procedure |
1. |
While depressing the lock, pull the two connector halves apart.
|
2. |
Use a small flat-blade tool to very carefully push the TPA towards the face of the connector on both sides of the connector. |
3. |
View of the male half of the connector with female terminals.
|
4. |
View of the female half of the connector with male terminals.
|
5. |
Use the J-38125-215 tool to release the terminals by inserting the tool into the terminal release cavity.
|
6. |
View of the female half of the connector with male terminals.
|
7. |
View of the male half of the connector with female terminals.
|
8. |
While holding the removal tool in place, gently pull the wire out of the back of the connector. Always remember never use force when pulling a terminal out of a connector.
|
9. |
Repair the terminal by following the
Repairing Connector Terminals
procedure.
|
10. |
Insert the repaired terminal back into the cavity. Repeat the diagnostic procedure to verify the repair and reconnect the connector bodies.
|