Power Mode Description and Operation
|
Power Mode Description and Operation
|
Serial Data Power Mode Master
|
Power to many of this vehicles circuits is controlled by the module that is designated the power mode master. The vehicle power mode master is the body control module (BCM). The ignition switch is a low current switch with multiple discrete ignition switch signals to the power mode master for determination of the power mode that will be sent over the serial data circuits to the other modules that need this information. The power mode master will also activate relays and other direct outputs of the power mode master as needed. The power mode master determines which power mode (Off, Accessory, Run, Crank Request) is required, and reports this information to other modules via serial data. Modules which have switched voltage inputs may operate in a default mode if the power mode serial data message does not match what the individual module can see from its own connections.
Relay Controlled Power Mode
|
The BCM uses the discrete ignition switch inputs Off/Run/Crank Voltage, Accessory Voltage, and Ignition 1 Voltage, to distinguish the correct power mode. The BCM, after determining the desired power mode, will activate the appropriate relays for that power mode.
The retained accessory power relay remains on for a timed period after the Ignition key is removed. Refer to
Retained Accessory Power Description and Operation
for more information on the retained accessory power function.
The BCM is able to control or perform all of the BCM functions in the awake state. The BCM enters the sleep state when active control or normal monitoring of system functions has stopped and a time limit has passed. The BCM must detect certain wake-up inputs before entering the awake state. The BCM monitors for these inputs during the sleep state.
The BCM will enter the awake state if any of the following wake-up inputs are detected:
•
|
Activity on the serial data line
|
•
|
Detection of a battery reconnect
|
•
|
Keyless entry or remote start message
|
The BCM will enter a sleep state when all of the following conditions exist:
•
|
No activity exists on the serial data line.
|
•
|
No outputs are commanded.
|
•
|
No delay timers are actively counting.
|
•
|
No wake-up inputs are present.
|
If all these conditions are met, the BCM will enter a low power or sleep condition.