SAAB WIS ONLINE

DTC B0283

DTC B0283

Diagnostic Instructions


Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.

Review Strategy Based Diagnosis for an overview of the diagnostic approach.

Diagnostic Procedure Instructions has overviews of all diagnostic categories.


DTC Descriptors

DTC B0283 02

Rear Defogger Circuit Short to Ground

DTC B0283 05

Rear Defogger Circuit High Voltage/Open

Diagnostic Fault Information

Circuit Short to Ground Open/High Resistance Short to Voltage Signal Performance
Rear Defog Relay Switch B+

1

1

-

-

Rear Defogger Relay Control

B0283 02

B0283 05

B0283 05

-

Rear Defogger Relay Coil Ground

-

B0283 05

1

-

1. Rear Defogger Inoperative



Circuit/System Description

When the HVAC control module receives a rear window defog request from the HVAC control faceplate, the HVAC control module will supply voltage to the relay coil. Battery positive voltage is supplied at all times to the relay switched input and the relay coil is always grounded. This allows current from the relay switched input to flow through the switch contacts and out the relay switched output to the rear window defogger grid.

Conditions for Running the DTC

Battery voltage must be between 9-16 V.

Conditions for Setting the DTC

B0283 02

The HVAC control module detects a short to ground in the relay control circuit.

B0283 05

The HVAC control module detects a short to voltage or an open/high resistance in the relay control circuit or an open/high resistance in the relay ground circuit.

Action Taken When the DTC Sets


If B0283 02 is current, the rear window defogger grid will operate continuously.

If B0283 05 is current, the rear window defogger grid will be inoperative.


Conditions for Clearing the DTC


The DTC will be current for as long as the fault is present.

When the fault is no longer present, the DTC will be a history DTC.

A history DTC will clear after 50 ignition cycles.


Reference Information

Schematic Reference

Defogger Schematics

Connector End View Reference

Component Connector End Views

Description and Operation

Rear Window Defogger Description and Operation

Electrical Information Reference


Circuit Testing

Connector Repairs

Testing for Intermittent Conditions and Poor Connections

Wiring Repairs


Scan Tool Reference

Control Module References for information on diagnostic tools

Circuit/System Verification

With the engine running, command the E18 rear window defroster grid ON and OFF with a diagnostic tool. The E18 rear window defroster grid should turn ON and OFF when changing between the commanded states.

Circuit/System Testing


1. Ignition OFF, disconnect the KR5 Rear Defogger Relay.

2. Test for less than 5 Ω between the ground circuit terminal 85 and ground.

3. If greater than the specified range, test the ground circuit for an open/high resistance.

4. Connect a test lamp between the control circuit terminal 85 and the ground circuit terminal 86.

5. Engine running, command the E18 Rear Defogger Grid ON and OFF by pressing and depressing the heated rear window switch. The test lamp should turn ON and OFF when changing between the commanded states.

6. If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the K33 HVAC Control Module.

7. If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the K33 HVAC Control Module.

8. If all circuits test normal, test or replace the KR5 Rear Defogger Relay.


Component Testing


Relay Test

1. Ignition OFF, disconnect the KR5 Rear Defogger Relay.

2. Test for 60-180 Ω between terminals 85 and 86.

3. If the not within the specified range, replace the KR5 Rear Defogger Relay.

4. Test for infinite resistance between the following terminals:

30 and 85

30 and 87

30 and 86

87 and 86

5. If not the specified value, replace the KR5 Rear Defogger Relay.

6. Install a 5 A fused jumper wire between relay terminal 86 and 12 V. Install a jumper wire between relay terminal 85 and ground. Test for less than 2 Ω between terminals 30 and 87.

7. If greater than the specified range, replace the KR5 Rear Defogger Relay.


Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.


Relay Replacement (Attached to Wire Harness)

Control Module References for HVAC control module replacement, setup and programming