"READ FUNCTIONS" command menu
"READ FUNCTIONS" command menu |
No.
|
ISAT
display
|
Function
|
1
|
INDUCTION AIR MASS
X.X V / X.XX gram/s |
Shows the input from the mass air flow sensor in
volts and the air
flow in grammes per second.
|
2
|
BATTERY VOLTAGE
XX.X V |
Shows the battery charge in volts
|
3
|
INTAKE AIR TEMP
X.X V / XXX °C |
Shows the input from the temperature sensor in the
intake manifold
(in V) and the air temperature (in °C).
|
4
|
COOLANT TEMPERATURE
XXX°C |
Shows the temperature of the coolant in °C
|
5
|
OXYGEN SENSOR 1-3-5
X.XX V |
Shows the input from the rear oxygen sensor in
volts
|
6
|
OXYGEN SENSOR 2-4-6
X.XX V |
Shows the input from the front oxygen sensor in
volts
|
7
|
THROTT POS SENSOR
X.X V / XX.X %% |
Shows the input from the throttle position sensor in
volts and the throttle opening in %%.
|
8
|
ENGINE RPM
XXXX RPM |
Shows the engine speed in rpm
|
9
|
INJECTION DURATION
XXX.X ms |
Shows the injection duration in ms.
|
10
|
ADAPT. SHORT 1-3-5
XX.X %% |
Shows short time adaptation (less than 20 minutes)
given as the
deviation relative to Lambda = 1.
|
11
|
ADAPT. LONG 1-3-5
XX.X %% |
Shows long time adaptation (more than 20 minutes)
given as the
deviation relative to Lambda = 1.
|
12
|
ADAPT. SHORT 2-4-6
XX.X %% |
Shows short time adaptation (less than 20 minutes)
given as the
deviation relative to Lambda = 1.
|
13
|
ADAPT. LONG 2-4-6
XX.X %% |
Shows long time adaptation (more than 20 minutes)
given as the
deviation relative to Lambda = 1.
|
14
|
IGNITION TIMING
XX.X GRADER |
Shows the current ignition timing in degrees BTDC.
|
15
|
KNOCK CONTROL
XX.X GRADER |
Shows ignition retard in degrees when knocking
occurs.
|
16
|
EVAP VALVE
XX.X %% |
Shows the EVAP canister purge valve opening
relationship expressed
as a percentage.
|
17
|
THROTTLE POSITION
XX.X %% |
Shows the degree of throttle opening expressed as
a percentage
|
18
|
WHEEL SPEED RF
XXX KM/H |
Shows the speed of the right-hand front wheel in
km/h.
|
19
|
ENGINE LOAD SIGNAL
XX.XX ms |
Shows the engine load signal (Tq) in
ms.
|
20
|
IAC VALVE
XX.X %%OPEN |
Shows the IAC valve's degree of closing
expressed as a percentage.
|
21
|
CALC. AIR MASS
XXX.X gram/s |
Shows the calculated air flow (air mass) through the
mass air flow
sensor in grammes per second.
|
22
|
ACTUAL AIR MASS
XXX.X gram/s |
Shows the actual air flow /air mass) through the mass air flow