No.

ISAT display

Function

1

INDUCTION AIR MASS

X.X V / X.XX gram/s

Shows the input from the mass air flow sensor in volts and the air flow in grammes per second.

2

BATTERY VOLTAGE

XX.X V

Shows the battery charge in volts

3

INTAKE AIR TEMP

X.X V / XXX °C

Shows the input from the temperature sensor in the intake manifold (in V) and the air temperature (in °C).

4

COOLANT TEMPERATURE

XXX°C

Shows the temperature of the coolant in °C

5

OXYGEN SENSOR 1-3-5

X.XX V

Shows the input from the rear oxygen sensor in volts

6

OXYGEN SENSOR 2-4-6

X.XX V

Shows the input from the front oxygen sensor in volts

7

THROTT POS SENSOR

X.X V / XX.X %%

Shows the input from the throttle position sensor in volts and the throttle opening in %%.

8

ENGINE RPM

XXXX RPM

Shows the engine speed in rpm

9

INJECTION DURATION

XXX.X ms

Shows the injection duration in ms.

10

ADAPT. SHORT 1-3-5

XX.X %%

Shows short time adaptation (less than 20 minutes) given as the deviation relative to Lambda = 1.

11

ADAPT. LONG 1-3-5

XX.X %%

Shows long time adaptation (more than 20 minutes) given as the deviation relative to Lambda = 1.

12

ADAPT. SHORT 2-4-6

XX.X %%

Shows short time adaptation (less than 20 minutes) given as the deviation relative to Lambda = 1.

13

ADAPT. LONG 2-4-6

XX.X %%

Shows long time adaptation (more than 20 minutes) given as the deviation relative to Lambda = 1.

14

IGNITION TIMING

XX.X GRADER

Shows the current ignition timing in degrees BTDC.

15

KNOCK CONTROL

XX.X GRADER

Shows ignition retard in degrees when knocking occurs.

16

EVAP VALVE

XX.X %%

Shows the EVAP canister purge valve opening relationship expressed as a percentage.

17

THROTTLE POSITION

XX.X %%

Shows the degree of throttle opening expressed as a percentage

18

WHEEL SPEED RF

XXX KM/H

Shows the speed of the right-hand front wheel in km/h.

19

ENGINE LOAD SIGNAL

XX.XX ms

Shows the engine load signal (Tq) in ms.

20

IAC VALVE

XX.X %%OPEN

Shows the IAC valve's degree of closing expressed as a percentage.

21

CALC. AIR MASS

XXX.X gram/s

Shows the calculated air flow (air mass) through the mass air flow sensor in grammes per second.

22

ACTUAL AIR MASS

XXX.X gram/s

Shows the actual air flow /air mass) through the mass air flow sensor in grammes per second.