Checking door switches
| Checking door switches |
| Fault symptom |
Doors disconnected from alarm
LED flashes during delay period
| Action |
| 1. |
Connect ISAT and select "READ VALUES", then select "DOOR". Open/close the doors and read off the display.
|
|
| 3. |
If the voltage is incorrect, check the wiring harness for short-circuit/open circuit by measuring the resistance between ICE control module connection pin 31 and theft alarm connection pin 3.
The resistance should be < 1 Ohm. |
|
| 4. |
If the malfunction remains despite the above checks, continue fault diagnosis according to Service Manual 3:5 Electrical system, instrument in section "Fault diagnosis ICE".
|
|