Checking door switches
Checking door switches |
Fault symptom |
Doors disconnected from alarm
LED flashes during delay period
Action |
1. |
Connect ISAT and select "READ VALUES", then select "DOOR". Open/close the doors and read off the display.
|
3. |
If the voltage is incorrect, check the wiring harness for short-circuit/open circuit by measuring the resistance between ICE control module connection pin 31 and theft alarm connection pin 3.
The resistance should be < 1 Ohm. |
4. |
If the malfunction remains despite the above checks, continue fault diagnosis according to Service Manual 3:5 Electrical system, instrument in section "Fault diagnosis ICE".
|