Checking the voltage +15
Checking the voltage +15 |
Fault symptom |
The alarm is not tripped when the ignition is turned on with activated alarm
Fuse 19 blows
Action |
1. |
Check that fuse 19 is intact and supplied with current.
|
2. |
Connect ISAT and select "READ VALUES" on the menu, then select "IGNITION +15". Turn the ignition key to on and read off the display.
ISAT must display "ON" in the drive and start positions. |
3. |
Connect BOB and check the voltage by measuring between the control module connection pin 17 and a good grounding point when the ignition is turned to drive and start positions.
The voltage must be approximately 12 V. |
4. |
Check the wiring harness for short-circuit/open circuit by measuring between the control module connection pin 17 and the fuse output side.
The resistance should be < 1 Ohm. |