Measured values, control module connections
Measured values, control module connections |
Pin
|
Colour
|
Component/ function
|
Test conditions
|
In/out
|
Measured value
|
Between X-Y
|
1
|
Green/black
|
Starter interlock relay
|
Ignition switch in starting position
|
Out
|
12 V
|
1-10
|
2
|
White/black
|
Diagnostics cable "K"
|
ISAT not connected
ISAT connected
|
|
0 V 12 V
|
2-10
|
3
|
Violet/white
|
Door switches via ICE
|
Ignition on
Door closed
Door open
|
In
|
12 V 0 V
|
3-10
|
4
|
Black/white
|
Tailgate switch
|
Tailgate closed Tailgate open
|
In
|
12 V 0 V
|
4-10
|
5
|
|
NC
|
|
|
|
|
6
|
|
NC
|
|
|
|
|
7
|
|
NC
|
|
|
|
|
8
|
|
NC
|
|
|
|
|
9
|
|
NC
|
|
|
|
|
10
|
Black
|
Power ground
|
|
In
|
< 0.1 V
|
10-
battery negative
|
11
|
Blue/brown
|
Unlock driver door from central locking control module
|
Deactivate alarm from driver door
|
In
|
12 V for 0.75 sec
|
11-10
|
12
|
Grey/black
|
Left direction indicator
|
Activate direction indicators with ISAT
"OFF"
"ON"
|
Out
|
0 V 12 V
|
12-10
|
13
|
Red
|
Voltage +30
|
|
In
|
12 V
|
13-10
|
14
|
|
NC
|
|
|
|
|
15
|
Blue/white
|
Lock tailgate
|
Activate alarm
Locked
Unlocked
|
In
|
5 V 0 V
|
15-10
|
16
|
Red/white
|
Switch, hood
|
Hood open Hood closed
|
In
|
0 V 2 V
|
16-10
|
17
|
Yellow/red
|
Voltage +15
|
Ignition on
|
In
|
12 V
|
17-10
|
18
|
Black/red
|
Voltage +50
|
Ignition switch in Start position
|
In
|
12 V
|
18-10
|
19
|
Grey/white
|
LED in dashboard
|
Activate diode with ISAT
"OFF"
"ON"
|
Out
|
0 V 2 V
|
19-10
|
20
|
Violet/white
|
Driver door lock from central locking control module
|
Activate alarm from driver door
|
In
|
12 V for 0.75 sec
|
20-10
|
21
|
|
NC
|
|
|
|
|
22
|
Black
|
Power ground, horn
|
|
In
|
< 0.1 V
|
22-10
|
23
|
|
NC
|
|
|
|
|
24
|
Yellow
|
Horn
|
Activate horn with ISAT
"OFF"
"ON"
|
Out
|
12 V 0 V
|
24-10
|
25
|
Green/black
|
Right direction indicators
|
Activate direction indicators with ISAT
"OFF"
"ON"
|
Out
|
0 V 12 V
|
25-10
|