Power supply +30
Power supply +30 |
Description of operation |
Positive voltage is supplied directly to the following components from battery 1:
• |
Starter motor 4 and on to generator 2
|
• |
Maxi fuse holder 501
- maxi fuses 1-5 Positive voltage is supplied from the battery via crimp J3 to: |
• |
Fuse board 342A
- fuses 1-3, 5, 12 - maxi fuses 1-3 |
• |
lighting relay 8
|
• |
dipswitch relay 8A
The following components are supplied via Maxi fuse 1 in maxi fuse holder 501 and crimp J89: |
• |
Fuse board 22A
- Fuses 1, 4, 11, 13, 23, 25, 26 and 34 The following components are supplied via Maxi fuse 2: |
• |
Fuse board 22A
- Fuses 2, 5, 10, 12, 16, 27, 28, 35 |
• |
Starter relay 517
|
• |
Light switch 10
|
• |
Fuel pump relay 102
|
• |
Fuel injection relay 229
The following components are supplied via Maxi fuse 3: |
• |
Ignition switch 20
The following components are supplied via Maxi fuse 4: |
• |
Ignition switch relay 21
|