Positive voltage is supplied directly to the following components from battery 1:


Starter motor 4 and on to generator 2

Maxi fuse holder 501

- maxi fuses 1-5

Positive voltage is supplied from the battery via crimp J3 to:

Fuse board 342A

- fuses 1-3, 5, 12

- maxi fuses 1-3

lighting relay 8

dipswitch relay 8A

The following components are supplied via Maxi fuse 1 in maxi fuse holder 501 and crimp J89:

Fuse board 22A

- Fuses 1, 4, 11, 13, 23, 25, 26 and 34

The following components are supplied via Maxi fuse 2:

Fuse board 22A

- Fuses 2, 5, 10, 12, 16, 27, 28, 35

Starter relay 517

Light switch 10

Fuel pump relay 102

Fuel injection relay 229

The following components are supplied via Maxi fuse 3:

Ignition switch 20

The following components are supplied via Maxi fuse 4:

Ignition switch relay 21