Control module voltage feed

Control module voltage feed


When the ignition key is in the drive position, the control module is supplied with +15 volts via fuse 18 to pin 9.

The control module is designed to operate on a power supply of between 7 and 16 volts. When the power supply is 7-9 volts, the diagnostics mode is turned off (no diagnostic trouble codes are generated) but the airbags will be triggered in the event of a collision.

If the power supply is continuously outside the operating range (9-16 V) so that the diagnostics mode cannot be activated, the warning lamp will come on after 20 seconds and then remain on.

Connector

The control module's connector has 4 short-circuit contacts which operate in pairs to short-circuit the leads connected to the two electric detonators as well as between the leads for the two warnings lamps and ground.

Diagnostics with ISAT

Communication with the ISAT scan tool is via pin 11. The data link connector is located under the dashboard below the steering wheel.