Pressure monitor
| Pressure monitor | 
| To remove | 
| 1. | Remove the grille. | |
| 2. | Drain the AC system of refrigerant. | |
| 3. | Unplug the connector and unscrew the three-stage pressure switch (A).   | |
| 4. | Hot-climate markets: Unplug the connector and unscrew the pressure switch (B). | |
| 5. | Plug the openings in the AC system. | |
| To fit | 
 
   
   | 1. | Hot-climate markets: Lubricate a new O-ring (C) with synthetic vaseline and fit it in place on the receiver. Screw the pressure monitor (B) in place and plug in the connector. | |
| 2. | Lubricate a new O-ring (D) with synthetic vaseline and fit it in place on the receiver. Screw the three-stage pressure switch (A) in place and plug in the connector. | |
| 3. | Fill up with compressor oil, carry out vacuum pumping of the AC system and fill up with refrigerant. | |

 
     
		