SAAB WIS ONLINE

Recirculation motor

Recirculation motor


To remove


1. Remove the glove box. See Service Manual 8:2 "Interior equipment".

2. Unplug the connector.


3. Remove the recirculation motor from the climate control unit housing by unhooking the locking tongues.

4. Disconnect the motor shaft from the recirculation flap lever. If the shaft is in its bottom position, you will have to crack the link at the fracture notch with a screwdriver.

5. Lift out the recirculation motor.


To fit



1. Reconnect the shaft of the recirculation motor to the lever of the recirculation flap.

2. Press the motor into the climate control unit housing.

3. Plug in the connector.

4. Refit the glove compartment. See Service Manual 8:2 Interior equipment .