OBTAIN READOUTS command menu
OBTAIN READOUTS command menu |
ISAT text/commands
|
Function
|
+54
ON/OFF |
Shows whether +54 is present or absent
|
PARKING HEATER ON/OFF
|
Shows parking heater status
|
BATTERY VOLTAGE
XX.X V |
Shows control module supply voltage
|
SUN SENSOR VALUE
X.XX V |
Voltage generated by the sun sensor in relation to light intensity (0-0.155 V)
|
SENSOR GROUND
X.XX V |
Shows the common sensor ground voltage
|
HEATED REAR WINDOW
ON/OFF |
Shows whether ICE operates the heated rear window relay
|
MIXED AIR SENSOR
X.XX V XX ° C XX ° F |
Shows the mixed air sensor voltage (0-4.98 V) and degrees in Celsius and Fahrenheit
|
INDOOR TEMP SENSOR
X.XX V XX ° C XX ° F |
Shows the interior temperature sensor voltage (0-4.98 V) and degrees in Celsius and Fahrenheit
|
PUSHBUTTONS
ON/OFF |
Shows whether any of the pushbuttons on the ACC unit are depressed
|